GOULDS GT 15 – 1 1/2 HP – Volts 115 – 230/60 Hz
Single Phase Centrifugal Pump

APPLICATIONS
Specifically designed for the following uses:
• Lawn sprinkling
• Irrigation
• Heat pumps
• Water transfer
• Air conditioning systems
• Dewatering
SPECIFICATIONS
Motor:
• NEMA standard open drip proof.
• 60 Hz, 3500 RPM.
• Stainless steel shaft.
• Single phase: æ-1_ HP, 115/230 V; 2 and 3 HP, 230 V only. Built-in overload with automatic
reset.
• Three phase: 230/460 V. Overload protection must be provided in starter unit. Starter and
• heaters (3) must be ordered separately.
• Optional TEFC motors are available.
Pump:
• Pipe connections: 1 1/2 NPT suction 1 1/2 NPT discharge
• Capacities: to 110 GPM at 5 foot suction lift.
• Heads: to 128 feet.
• Reprime capabilities: to 25 feet suction lift.
• Maximum working pressure: 125 PSIG.
• Maximum water temperature: 140_ F (60_ C).
• Rotation: clockwise when viewed from motor end.
FEATURES
Self-Priming Design
Once pump is primed, filled with water, it never needs priming again even if water level drops below
the end of the suction pipe. Pumping resumes once the water level rises above the end of the suction
pipe.
Diffuser (Guidevane)
Bolt down diffuser provides positive alignment with impeller. Diffuser has stainless wear ring for
extended performance in abrasive conditions. F.D.A. compliant, injection molded, food grade, glass
filled LexanÆ for durability and abrasion resistance.
Serviceable
Back pullout design allows disassembly of pump for service without disturbing piping.Two
compartment motor for easy access to motor wiring and replaceable components.
Corrosion Resistant
Electro-coat paint process is applied inside and out, then baked on.
Impeller
F.D.A. compliant, glass filled NorylÆ. Corrosion and abrasion resistant.
Casing
Cast iron construction. Four (4) bolt, back pull-out design. Tapped openings provided for vacuum
gauge and casing drain.
Mechanical Seal
Carbon/ceramic faces, BUNA elastomers. 300 series stainless steel metal parts. Pump design prevents
the seal from running dry.
Powered for Continuous Operation
Pump ratings are within the motor manufacturer's recommended working limits. Can be operated
continuously without damage.
Get in Touch
CONTACT
INFORMATION
Reach out to South Florida Pumps today for the area’s
best in sales and service for water pumps, electric motors,
sewage and storm lift stations, and more.
- 7850 NW 71st St, Miami, FL 33166
- (786) 761-2826